CVE-2021-22681
Rockwell Multiple Products: Insufficient Protected Credentials
As of , CVE-2021-22681 in Rockwell Multiple Products is on CISA's list of exploited vulnerabilities: CISA listed it on . Our patch-first group: Patch this week.
- Exploited
- Yes: CISA listed it on 5 March 2026
- US federal deadline
- 26 March 202621 days after CISA listed it. US federal civilian agencies must fix it by then.
- Used in ransomware campaigns
- Not known to CISA
- EPSS score
- 0.64Higher than 99% of the CVEs EPSS scores. EPSS estimates the chance of exploitation activity in the next 30 days.
- Public exploit
- None foundNeither Metasploit nor Exploit-DB lists one.
- Fix
- Vendor advice: support.rockwellautomation.comLinks below, from CISA's entry.
What CISA says to do
Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
CISA's required action
What the flaw is
Multiple Rockwell products contain an insufficient protected credentials vulnerability. Studio 5000 Logix Designer software may allow a key to be discovered. This key is used to verify Logix controllers are communicating with Rockwell Automation design software. If successfully exploited, this vulnerability could allow an unauthorized application to connect with Logix controllers. To leverage this vulnerability, an unauthorized user would require network access to the controller.
CISA's description
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.
The CVE record's description, from icscert
- CVE published
- 3 March 2021
- Assigned by
- icscert
- CVSS
- 9.8 Critical (CVSS 3.1, from CISA-ADP)
- CWE-522
- Insufficiently Protected Credentials
- CISA SSVC, exploitation
- active
- CISA SSVC, automatable
- yes
- CISA SSVC, technical impact
- total
Timeline
- The CVE record was published.
- CISA added it to its list of exploited vulnerabilities.
- The US federal deadline to fix it.
Read further
- CVE recordcve.org
- NVD entrynvd.nist.gov
- CISA's catalogcisa.gov
- EPSS for this CVEapi.first.org