CISA list

As of , CVE-2016-8562 in Siemens SIMATIC CP is on CISA's list of exploited vulnerabilities: CISA listed it on . Our patch-first group: Patch soon.

CVE-2016-8562

Siemens SIMATIC CP: 1543-1 Improper Privilege Management. Exploited, and in our Patch soon group.

Our patch-first group

Patch soon

CISA's required action

Apply updates per vendor instructions.

Patch infofixed versions and vendor advice

What to install

  • Affects Siemens SIMATIC CP.

The record's list of affected products gives no versions.

EPSS score
0.04
Higher than 89% of the CVEs EPSS scores.

EPSS estimates the chance of exploitation activity in the next 30 days.

Exploited
Yes CISA listed it on 3 March 2022
US federal deadline
24 March 2022 21 days after CISA listed it. US federal civilian agencies must fix it by then.
Used in ransomware campaigns
Not known to CISA
EPSS when listed
0.01 on 3 March 2022 EPSS on the day CISA listed it.
Public exploit
None found Neither Metasploit nor Exploit-DB lists one.

Since listing

EPSS since listing

0.000.501.000.50: EPSS line for Patch this weekListed by CISAEPSS model v2023.03.01EPSS model v2025.03.14EPSS model v2026.06.1520232024202520260.000.501.00Listed by CISAEPSS model v2023.03.01EPSS model v2025.03.14EPSS model v2026.06.1520232025

EPSS for CVE-2016-8562 since CISA listed it, on the days its value to 2 decimals changed. EPSS scores by FIRST.

Show the numbers
FromEPSS
0.01
0.02
0.06
0.05
0.22
0.05
0.15
0.19
0.04

Timeline

What happened when

  1. The CVE record was published.
  2. CISA added it to its list of exploited vulnerabilities.
  3. The US federal deadline to fix it.

CISA's required action

What CISA says to do

Apply updates per vendor instructions.

Read further: CISA's catalog

The flaw

What the flaw is

An improper privilege management vulnerability exists within the Siemens SIMATIC Communication Processor (CP) that allows a privileged attacker to remotely cause a denial of service.

CISA's description

A vulnerability has been identified in SIMATIC CP 1543-1 (All versions < V2.0.28), SIPLUS NET CP 1543-1 (All versions < V2.0.28). Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these variables could reduce the availability or cause a denial-of-service.

The CVE record's description, from mitre

CVE published
18 November 2016
Assigned by
mitre
CVSS
7.5 High (CVSS 3.1, from CISA-ADP)
CWE-20
Improper Input Validation
CISA SSVC, exploitation
active
CISA SSVC, automatable
no
CISA SSVC, technical impact
total
Sources
  • CVE records: Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation (source). Licence: CVE Program Terms of Use
  • CWE names: Copyright © 2006-2026, The MITRE Corporation. CWE, CWSS, CWRAF, and the CWE logo are trademarks of The MITRE Corporation (source). Licence: CWE Terms of Use
  • EPSS scores by FIRST (https://www.first.org/epss/), generated by Empirical Security (source)